Spray - CRC smoke detector test spray

Technical Data Sheet ACN 000 725 833 Place of Origin: China I. Product Description CRC Smoke Tester conveniently tests the functional capability of a smoke detector. The CRC Smoke Tester can be sprayed while standing on the floor eliminating the need  more information

SAR 66.41

+  

Earn loyalty points with this purchase

Rewards  

product sku

Z.173018.1722469149106238

Weight

71.0 g

Quantity

This product is out of stock

Notify me when product is available

share product

product description

Technical Data Sheet ACN 000 725 833

Place of Origin: China

I. Product Description CRC Smoke Tester conveniently tests the functional capability of a smoke detector. The CRC Smoke Tester can be sprayed while standing on the floor eliminating the need to climb ladders or chairs. Ideal for residential or commercial detectors, the CRC Smoke Tester is safe and easy to use. All it takes is a 3-second CRC Smoke Test. Additionally, the CRC Smoke Tester checks for obstructions or debris that block the detector openings and prevent smoke from properly entering the sensing chamber. This important safety test is not accomplished by pressing a test button. II. Applications

Recommended for testing the functional capability of commercial or residential smoke detectors.

III. Features and Benefits

· Simulates smoke. Provides a real functional test of smoke detectors.

· Aerosol spray extends user reach to a distance of up to 1 meter. Allows testing to be performed while safely standing on the floor.

· Convenient package. Makes testing easy, increasing the likelihood of testing detectors on a regular basis.

· No harmful residuals. Smokeless aerosol ensures detectors remain in good working order after each test without carbon residue buildup.

· Plastic safe. Will not damage plastic housing or internal circuitry.

· Non-staining. Will not discolor painted ceilings, walls, or smoke detectors.

· No Class I or II ozone depleting chemicals. Provides superior performance while meeting EPA regulations for CFCs.

· SD[L] Safety Data Label. Provides immediate access to current safety information in the event of an accident or OSHA inspection. Helps comply with OSHA Hazard Communications Standard 29 CFR 1910.1200

IV. Physical Properties No Propellant Flash Point 13.33 (TCC) Boiling Point (Initial) 77.77 (Initial) Odor Faint Solubility in Alcohol Noticeable in Water Appearance Colorless % Volatile 92% Vapor Density 1.6 Air = 1 Specific Gravity 0.81 VOC Content (VOC) 810 g/L Freezing Point Not Specified Sare Title 111, Sect. 313 Chemicals No Hydrocarbon Propellant 65 No.

V. Specifications and Approvals · NSN #6850-00-050-0659.

· NFPA accepted as a means of testing smoke detectors, per NFPA Table 10.4.2.2.#13(g).

· Underwriters Laboratories (UL) listed.

VII. Performance Characteristics: Passed Bellcore Test (Compatibility with Plastics).

VII. Directions · Shake well. Hold canister 600mm - 1.2m below smoke detector and spray for 2-3 seconds.

· If alarm does not sound within 5 seconds, repeat process. Some detectors have a built-in delay to reduce false alarms.

· If unit still does not sound, immediately inspect unit for any defects, debris, or dead batteries.

· To quickly silence an activated alarm, vent air through detector vents.

· Do not over-spray. Over-spraying may reduce sensitivity until product is completely evaporated.

· For detectors connected to sprinklers, halo systems, or central monitoring systems, ensure unit is in test mode before testing with CRC smoke tester.

VIII. Package Description Part Number: 2105 Container Size: 6oz Aerosol

IX. Disposal

Disposal requirements vary by state and local regulations. All used and unused products must be disposed of in accordance with local, state, and commonwealth laws and regulations.

X. Special Use Warnings

Aerosol Cans

Do not puncture, burn or store above 500°C. Exposure to high temperatures may cause the can to burst. Do not place in direct sunlight or near any heat source. Aerosol cans will conduct electricity. Keep away from all live electrical sources including battery terminals, solenoids, circuit boards and other electronic components. Failure to observe this warning may result in serious injury from fire and/or electric shock.

General

Use only in a well-ventilated area. Ventilation may be improved by opening a window or door or providing mechanical assistance. Avoid continuous breathing of vapors and mist. Avoid contact with skin and eyes. If ventilation is inadequate, wear respiratory protection. For further information on short-term and long-term exposure, see the Material Safety Data Sheet for this product.

Product Warranty: CRC provides a conditional warranty on this product for 5 years from the date of manufacture.

Disclaimer: All information contained in this data sheet is based on testing conducted by CRC Industries (Aust.) Pty. Ltd. All products should be tested for suitability for a particular application prior to actual use. CRC Industries (Aust.) Pty. Ltd. makes no representations or warranties of any kind with respect to this data.